{"id":1421,"date":"2026-05-05T09:13:32","date_gmt":"2026-05-05T09:13:32","guid":{"rendered":"https:\/\/innome.de\/?page_id=1421"},"modified":"2026-05-05T09:13:33","modified_gmt":"2026-05-05T09:13:33","slug":"specplate","status":"publish","type":"page","link":"https:\/\/innome.de\/en\/specplate\/","title":{"rendered":"SpecPlate"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-global-padding is-layout-constrained wp-container-core-group-is-layout-a61a3a89 wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group alignfull has-global-padding is-content-justification-center is-layout-constrained wp-container-core-group-is-layout-b6632178 wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--28);margin-bottom:var(--wp--preset--spacing--28);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--16);padding-left:var(--wp--preset--spacing--16);flex-basis:100%\">\n<div class=\"wp-block-group has-global-padding is-content-justification-center is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-left\">SpecPlate - The better standard for plate-based UV\/VIS spectroscopy | 4 measuring chambers, back injection principle<\/h2>\n\n\n\n<p class=\"has-text-align-left\"><strong>Revolutionary 96-well plate with 4 physical layer heights (100-2000 \u00b5m) - measures highly concentrated samples without dilution steps, eliminates meniscus problems, only 36 \u00b5l sample volume<\/strong><\/p>\n\n\n\n<p>The <strong>SpecPlate<\/strong> sets a new standard in plate-based UV\/VIS spectroscopy. The unique <strong>Back-moulding principle<\/strong> fills 4 closed measuring chambers with defined layer heights (100 \u00b5m, 700 \u00b5m, 1400 \u00b5m, 2000 \u00b5m) via a single inlet - no meniscus, no pipetting errors, no dilution.<\/p>\n\n\n\n<p><strong>Manufactured by innoME<\/strong> in close development partnership with <a href=\"https:\/\/phabioc.com\/produkte\/#specplate\" target=\"_blank\">Phabioc<\/a> - made of high-quality COC (cyclo-olefin copolymer) for UV transparency from 220 nm. ANSI\/SLAS-compliant, compatible with all standard plate readers. Order directly from <a href=\"https:\/\/shop.innome.de\/products\/specplate-low-binding-uv-vis?srsltid=AfmBOorSIbSHMDVtbGZs8wmIsMVtoUoRdjZluPIwo2mGFGMPgxzDoh_Y\">innoME Shop<\/a>.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/shop.innome.de\/products\/specplate-low-binding-uv-vis?srsltid=AfmBOorSIbSHMDVtbGZs8wmIsMVtoUoRdjZluPIwo2mGFGMPgxzDoh_Y\" style=\"border-top-left-radius:100px;border-top-right-radius:100px;border-bottom-left-radius:100px;border-bottom-right-radius:100px\">Order now!<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--16);padding-left:var(--wp--preset--spacing--16);flex-basis:100%\">\n<figure class=\"wp-block-image aligncenter size-full has-custom-border\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"1368\" src=\"https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623.jpg\" alt=\"SpecPlate 96-Well UV\/VIS 4 measuring chambers Back injection principle innoME Phabioc\" class=\"wp-image-1032\" style=\"border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-left-radius:10px;border-bottom-right-radius:10px\" srcset=\"https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623.jpg 1920w, https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623-300x214.jpg 300w, https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623-1024x730.jpg 1024w, https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623-768x547.jpg 768w, https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623-1536x1094.jpg 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"specplate-kpi\">\n<style>\n.specplate-kpi{font-family:Poppins,system-ui,sans-serif}.specplate-kpi *{box-sizing:border-box}\n.specplate-kpi__title{margin:0 0 28px;color:#009FE3;font-size:42px;font-weight:600;letter-spacing:-0.03em}\n.specplate-kpi__grid{display:grid;grid-template-columns:repeat(4,1fr);gap:20px}\n.spk-card{background:#fff;border:1px solid rgba(15,47,58,0.08);border-radius:22px;padding:28px 20px;text-align:center;box-shadow:0 8px 24px rgba(15,47,58,0.05);transition:border-color .25s,box-shadow .25s,transform .25s}\n.spk-card:hover{border-color:rgba(0,159,227,0.3);box-shadow:0 16px 36px rgba(15,47,58,0.10);transform:translateY(-3px)}\n.spk-card__value{font-size:48px;font-weight:700;color:#009FE3;line-height:1;margin-bottom:6px}\n.spk-card__unit{font-size:18px;font-weight:400;color:#00BFBA}\n.spk-card__label{font-size:14px;font-weight:600;color:#0f2f3a;margin-bottom:6px;margin-top:8px}\n.spk-card__desc{font-size:13px;color:#5d7680;line-height:1.5}\n@media(max-width:900px){.specplate-kpi__grid{grid-template-columns:repeat(2,1fr)}}\n@media(max-width:480px){.specplate-kpi__grid{grid-template-columns:1fr}}\n<\/style>\n<h2 class=\"specplate-kpi__title\">What makes the SpecPlate unique<\/h2>\n<div class=\"specplate-kpi__grid\">\n<div class=\"spk-card\">\n<div class=\"spk-card__value\">4\u00d7<span class=\"spk-card__unit\"><\/span><\/div>\n<div class=\"spk-card__label\">More data points<\/div>\n<div class=\"spk-card__desc\">4 layer heights = 4 measured values per well - up to 384 data points per plate<\/div>\n<\/div>\n<div class=\"spk-card\">\n<div class=\"spk-card__value\">36<span class=\"spk-card__unit\"> \u00b5l<\/span><\/div>\n<div class=\"spk-card__label\">Sample volume<\/div>\n<div class=\"spk-card__desc\">Only 36 \u00b5l for all 4 measuring points - ideal for valuable or scarce samples<\/div>\n<\/div>\n<div class=\"spk-card\">\n<div class=\"spk-card__value\">70<span class=\"spk-card__unit\">%<\/span><\/div>\n<div class=\"spk-card__label\">Less consumables<\/div>\n<div class=\"spk-card__desc\">Elimination of dilution steps - up to 70% cost reduction<\/div>\n<\/div>\n<div class=\"spk-card\">\n<div class=\"spk-card__value\">0<span class=\"spk-card__unit\"><\/span><\/div>\n<div class=\"spk-card__label\">Dilution steps<\/div>\n<div class=\"spk-card__desc\">Direct measurement of highly concentrated samples - no errors due to dilution<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-app-mat\">\n<style>\n.innome-app-mat{background:#fff;font-family:Poppins,system-ui,sans-serif}.innome-app-mat *{box-sizing:border-box}.innome-app-mat__container{max-width:1340px;margin:0 auto}.innome-app-mat__grid{display:grid;grid-template-columns:1fr 1fr;gap:28px;align-items:stretch}.innome-app-mat__card{background:#fff;border:1px solid rgba(15,47,58,0.08);border-radius:24px;padding:32px;box-shadow:0 14px 34px rgba(15,47,58,0.05);height:100%}.innome-app-mat__title{margin:0 0 18px;color:#009FE3;font-size:36px;font-weight:600;letter-spacing:-0.03em}.innome-app-mat__subtitle{margin:0 0 22px;color:#5d7680;font-size:16px;line-height:1.7}\n.specplate-chambers{display:flex;flex-direction:column;gap:12px;margin-top:16px}\n.spc{display:flex;align-items:center;gap:16px;background:#f8fbfd;border:1px solid rgba(0,159,227,0.15);border-radius:14px;padding:14px 18px}\n.spc__height{font-size:22px;font-weight:700;color:#009FE3;min-width:90px;font-family:Poppins,sans-serif}\n.spc__bar{height:10px;background:linear-gradient(90deg,#009FE3,#00BFBA);border-radius:999px;flex-shrink:0}\n.spc__label{font-size:13px;color:#5d7680;line-height:1.4}\n.spc__label strong{color:#0f2f3a;display:block;font-size:14px;margin-bottom:2px}\n.innome-app-mat__table-wrap{overflow-x:auto;border:1px solid rgba(15,47,58,0.08);border-radius:18px}.innome-app-mat__table{width:100%;border-collapse:collapse}.innome-app-mat__table th,.innome-app-mat__table td{padding:14px 18px;text-align:left;border-bottom:1px solid rgba(15,47,58,0.08);border-right:1px solid rgba(15,47,58,0.08);font-size:14px}.innome-app-mat__table th:last-child,.innome-app-mat__table td:last-child{border-right:none}.innome-app-mat__table tr:last-child td{border-bottom:none}.innome-app-mat__table thead th{background:rgba(0,159,227,0.06);color:#009FE3;font-weight:600}.innome-app-mat__table tbody td:first-child{font-weight:600;color:#0f2f3a}.innome-app-mat__table tbody td:not(:first-child){color:#5d7680}\n@media(max-width:1100px){.innome-app-mat__grid{grid-template-columns:1fr}}\n<\/style>\n<div class=\"innome-app-mat__container\">\n<div class=\"innome-app-mat__grid\">\n \n<div class=\"innome-app-mat__card\">\n<h2 class=\"innome-app-mat__title\">The back-injection principle<\/h2>\n<p class=\"innome-app-mat__subtitle\">Pipette the sample once - fill 4 layer heights simultaneously:<\/p>\n<p style=\"font-size:15px;color:#0f2f3a;line-height:1.7;margin:0 0 18px\">The sample is analysed via a single <strong>Inlet<\/strong> and flows through the 4 consecutive measuring chambers. The liquid rises in the inlet and outlet as a levelling vessel - the measuring chambers are completely filled, without a meniscus or air bubble. Pipetting errors are compensated for by the level equalisation chambers.<\/p>\n<div class=\"specplate-chambers\">\n<div class=\"spc\">\n<span class=\"spc__height\">100 \u00b5m<\/span>\n<div class=\"spc__bar\" style=\"width:10px\"><\/div>\n<div class=\"spc__label\"><strong>Shortest shift<\/strong>Measure very high concentrations - where standard plates saturate<\/div>\n<\/div>\n<div class=\"spc\">\n<span class=\"spc__height\">700 \u00b5m<\/span>\n<div class=\"spc__bar\" style=\"width:35px\"><\/div>\n<div class=\"spc__label\"><strong>Short shift<\/strong>High concentrations without dilution<\/div>\n<\/div>\n<div class=\"spc\">\n<span class=\"spc__height\">1400 \u00b5m<\/span>\n<div class=\"spc__bar\" style=\"width:70px\"><\/div>\n<div class=\"spc__label\"><strong>Middle layer<\/strong>Standard concentration range<\/div>\n<\/div>\n<div class=\"spc\">\n<span class=\"spc__height\">2000 \u00b5m<\/span>\n<div class=\"spc__bar\" style=\"width:100px\"><\/div>\n<div class=\"spc__label\"><strong>Longest shift<\/strong>Low concentrations - maximum sensitivity<\/div>\n<\/div>\n<\/div>\n<\/div>\n \n<div class=\"innome-app-mat__card\">\n<h2 class=\"innome-app-mat__title\">SpecPlate vs. standard plate<\/h2>\n<div class=\"innome-app-mat__table-wrap\">\n<table class=\"innome-app-mat__table\">\n<thead><tr><th>Property<\/th><th>Standard 96-well<\/th><th>SpecPlate<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Layer height<\/td><td>Variable (meniscus)<\/td><td>4 \u00d7 defined (100-2000 \u00b5m)<\/td><\/tr>\n<tr><td>Measuring points\/well<\/td><td>1<\/td><td>4 (simultaneously)<\/td><\/tr>\n<tr><td>Sample volume<\/td><td>100-300 \u00b5l<\/td><td>36 \u00b5l<\/td><\/tr>\n<tr><td>Meniscus problem<\/td><td>Yes - Measurement error<\/td><td>No - closed chamber<\/td><\/tr>\n<tr><td>Dilution necessary?<\/td><td>With high conc.<\/td><td>No<\/td><\/tr>\n<tr><td>Pipetting errors<\/td><td>Affects measurement<\/td><td>Compensated (level vessel)<\/td><\/tr>\n<tr><td>UV off<\/td><td>~320 nm (PS)<\/td><td>220 nm (COC)<\/td><\/tr>\n<tr><td>Disc reader<\/td><td>96-Well Reader<\/td><td>384-well reader (standard)<\/td><\/tr>\n<tr><td>Slope method<\/td><td>Not possible<\/td><td>Built-in - increased precision<\/td><\/tr>\n<tr><td>Costs\/data point<\/td><td>Standard<\/td><td>Up to 70% cheaper<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n \n<\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"sb-categories\">\n<h2 class=\"sb-categories__title\">Product Information<\/h2>\n<div class=\"sb-categories__nav\">\n<button class=\"sb-cat-btn active\" data-tab=\"hinterspritzen\">Back-moulding principle<\/button>\n<button class=\"sb-cat-btn\" data-tab=\"schichten\">4 layer heights<\/button>\n<button class=\"sb-cat-btn\" data-tab=\"slope\">Slope method<\/button>\n<button class=\"sb-cat-btn\" data-tab=\"coc\">COC material<\/button>\n<button class=\"sb-cat-btn\" data-tab=\"integration\">Disc reader integration<\/button>\n<button class=\"sb-cat-btn\" data-tab=\"hersteller\">innoME as manufacturer<\/button>\n<\/div>\n<div class=\"sb-categories__content\">\n<div class=\"sb-cat-panel active\" data-content=\"hinterspritzen\">\n<h3>The back injection principle - no menisci, no error<\/h3>\n<p>The 4 measuring chambers are connected via a single inlet <strong>Filled from behind<\/strong> - the sample flows through the cascaded chambers and rises in the inlet and outlet as communicating level vessels. The chambers are filled completely and bubble-free - without a meniscus at the measuring zone. This means that the light beam of the plate reader always hits a defined, flat liquid layer - no scattering, no measurement errors due to surface curvature. Even pipetting errors (\u00b15 \u00b5l) are fully compensated for by the level equalisation chambers.<\/p>\n<\/div>\n<div class=\"sb-cat-panel\" data-content=\"schichten\">\n<h3>4 physically defined layer heights in one well<\/h3>\n<p>Each SpecPlate measuring structure contains 4 chambers with precisely defined heights: <strong>100 \u00b5m, 700 \u00b5m, 1400 \u00b5m, 2000 \u00b5m<\/strong>. This physical \u201edilution\u201c through layer height variation completely replaces classic sample dilution:<br><br>\n<strong>100 \u00b5m<\/strong>Very high concentrations (which saturate the detector in standard plates) measurable<br>\n<strong>700 \u00b5m<\/strong>High concentrations without dilution<br>\n<strong>1400 \u00b5m<\/strong>Medium concentration range<br>\n<strong>2000 \u00b5m<\/strong>Low concentrations with maximum sensitivity<br><br>\nResult: 4 data points over a wide concentration range - simultaneously, from a single 36 \u00b5l sample.<\/p>\n<\/div>\n<div class=\"sb-cat-panel\" data-content=\"slope\">\n<h3>Slope method - increased measurement accuracy through regression analysis<\/h3>\n<p>The 4 data points of the different layer heights enable the application of the <strong>Slope method (ascent method)<\/strong>Linear regression of the absorption values against the layer height results in a regression line (typically R\u00b2 &gt; 0.999). The slope of this line is proportional to the concentration - and more precise than a single measured value, as outliers are equalised by the regression.<br><br>\nExample: 5 mg\/ml lysozyme measurement with SpecPlate \u2192 R\u00b2 = 0.9995, y = 0.0011x + 0.0355. This statistical validation significantly increases the reproducibility compared to individual measurements in standard plates.<\/p>\n<\/div>\n<div class=\"sb-cat-panel\" data-content=\"coc\">\n<h3>COC (cyclo-olefin copolymer) - the better material for UV\/VIS<\/h3>\n<p>The entire SpecPlate is made from high-quality <strong>COC (Cyclo-Olefin-Copolymer)<\/strong> the proven material for spectroscopic applications in the UV range:<br><br>\n<strong>UV-transparent from 220 nm<\/strong>Measurements at 220, 230, 260, 280 nm possible without problems (PS only from ~320 nm)<br>\n<strong>Solvent resistant<\/strong>Resistant to DMSO, acetone and other organic solvents - important for drug discovery<br>\n<strong>Low inherent fluorescence<\/strong>Minimal autofluorescence for precise fluorescence measurements<br>\n<strong>Low protein adsorption<\/strong>Minimised sample losses at the plate surface<\/p>\n<\/div>\n<div class=\"sb-cat-panel\" data-content=\"integration\">\n<h3>Seamless integration into standard workflows<\/h3>\n<p>The SpecPlate was developed strictly <strong>ANSI\/SLAS Standards<\/strong> developed - no refitting, no new equipment necessary:<br><br>\n<strong>Inlet positions in 96-well format<\/strong>Standard pipetting robots fill the SpecPlate like a normal 96-well plate<br>\n<strong>Reading window in 384-well format<\/strong>Standard 384-well plate readers (Tecan, BioTek, PerkinElmer, BMG) read all 4 chambers automatically<br>\n<strong>Sealing film compatible<\/strong>Special translucent sealing film available for volatile or toxic samples<br>\n<strong>Automation-ready<\/strong>Direct integration into high-throughput liquid handling systems<\/p>\n<\/div>\n<div class=\"sb-cat-panel\" data-content=\"hersteller\">\n<h3>innoME as manufacturer - Phabioc as development partner<\/h3>\n<p>The SpecPlate is a joint product from <strong>innoME GmbH (Espelkamp)<\/strong> as a manufacturer and <strong>Phabioc GmbH<\/strong> as a development partner and sales organisation:<br><br>\n<strong>innoME<\/strong>Production of the SpecPlate in Germany - precision injection moulding of the COC structure with the 4 defined measuring chambers, quality assurance, packaging<br>\n<strong>Phabioc<\/strong>Scientific development, characterisation, distribution, scientific support<br><br>\nOrder: <a href=\"https:\/\/shop.innome.de\/products\/specplate-low-binding-uv-vis?srsltid=AfmBOorSIbSHMDVtbGZs8wmIsMVtoUoRdjZluPIwo2mGFGMPgxzDoh_Y\" target=\"_blank\">shop.innome.de<\/a><br>\nEnquiries for OEM or larger quantities directly to innoME.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<script>\ndocument.querySelectorAll('.sb-cat-btn').forEach(btn => {\nbtn.addEventListener('click', function() {\ndocument.querySelectorAll('.sb-cat-btn').forEach(b => b.classList.remove('active'));\nthis.classList.add('active');\nconst tab = this.getAttribute('data-tab');\ndocument.querySelectorAll('.sb-cat-panel').forEach(panel => {\npanel.classList.toggle('active', panel.getAttribute('data-content') === tab);\n});\n});\n});\n<\/script>\n<style>\n.sb-categories{padding-top:30px;font-family:Poppins,system-ui,sans-serif}.sb-categories__title{font-weight:500;font-size:32px;margin:0 0 30px;color:#009fe3}.sb-categories__nav{display:flex;flex-wrap:wrap;gap:14px;margin-bottom:26px}.sb-cat-btn{background:#e9e9e9;border:none;padding:14px 20px;border-radius:999px;font-weight:500;cursor:pointer;transition:0.2s;font-family:inherit}.sb-cat-btn:hover{background:#dcdcdc}.sb-cat-btn.active{background:#00BFBA;color:#fff}.sb-categories__content{background:#fff;padding:32px 34px;border-radius:20px;box-shadow:0 20px 40px rgba(0,0,0,0.08)}.sb-cat-panel{display:none}.sb-cat-panel.active{display:block;animation:fadeIn 0.3s ease}.sb-cat-panel h3{font-weight:500;font-size:22px;margin:0 0 15px;color:#000}.sb-cat-panel p{margin:0;font-size:16px;line-height:1.7;color:#000}.sb-cat-panel a{color:#009FE3}@keyframes fadeIn{from{opacity:0}to{opacity:1}}@media(max-width:900px){.sb-cat-btn{width:100%}.sb-categories__content{padding:24px}}\n<\/style>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-specs-grid\">\n<style>\n.innome-specs-grid{background:#fff;font-family:Poppins,system-ui,sans-serif}.innome-specs-grid *{box-sizing:border-box}.innome-specs-grid__container{max-width:1340px;margin:0 auto}.innome-specs-grid__title{margin:0 0 28px;color:#009FE3;font-size:42px;font-weight:600;letter-spacing:-0.03em}.innome-specs-grid__grid{display:grid;grid-template-columns:repeat(4,minmax(0,1fr));gap:22px}.innome-specs-grid__item{border:1px solid rgba(15,47,58,0.08);border-radius:18px;padding:22px;transition:border-color .25s,box-shadow .25s,transform .25s}.innome-specs-grid__item:hover{border-color:rgba(0,159,227,0.25);box-shadow:0 12px 30px rgba(15,47,58,0.08);transform:translateY(-2px)}.innome-specs-grid__label{margin:0 0 6px;color:#0f2f3a;font-size:17px;font-weight:600}.innome-specs-grid__value{margin:0;color:#5d7680;font-size:15px;line-height:1.65}@media(max-width:1000px){.innome-specs-grid__grid{grid-template-columns:repeat(2,1fr)}}@media(max-width:640px){.innome-specs-grid__grid{grid-template-columns:1fr}}\n<\/style>\n<div class=\"innome-specs-grid__container\">\n<h2 class=\"innome-specs-grid__title\">Technical Specifications<\/h2>\n<div class=\"innome-specs-grid__grid\">\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Format (Inlet)<\/h3><p class=\"innome-specs-grid__value\">96-well arrangement (filling)<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Format (read)<\/h3><p class=\"innome-specs-grid__value\">384-well arrangement (4 chambers \u00d7 96)<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Layer heights<\/h3><p class=\"innome-specs-grid__value\">100 \u00b5m \/ 700 \u00b5m \/ 1400 \u00b5m \/ 2000 \u00b5m<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Sample volume<\/h3><p class=\"innome-specs-grid__value\">36 \u00b5l (fills all 4 chambers completely)<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Material<\/h3><p class=\"innome-specs-grid__value\">COC (cyclo-olefin copolymer) complete<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">UV transmission from<\/h3><p class=\"innome-specs-grid__value\">220 nm - full UV\/VIS range<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Solvent resistance<\/h3><p class=\"innome-specs-grid__value\">DMSO, acetone, organic solvents<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Standard<\/h3><p class=\"innome-specs-grid__value\">ANSI\/SLAS compliant<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Disc reader<\/h3><p class=\"innome-specs-grid__value\">All standard 384-well readers (Tecan, BioTek, PerkinElmer, BMG)<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Sealing film<\/h3><p class=\"innome-specs-grid__value\">Optional - translucent for volatile samples (Art. 400101)<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Packaging<\/h3><p class=\"innome-specs-grid__value\">40 pieces\/box (Art. 400100)<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Manufacturer<\/h3><p class=\"innome-specs-grid__value\">innoME GmbH, Germany | Distribution: Phabioc<\/p><\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-app-mat2\">\n<style>\n.innome-app-mat2{background:#fff;font-family:Poppins,system-ui,sans-serif}.innome-app-mat2 *{box-sizing:border-box}.innome-app-mat2__container{max-width:1340px;margin:0 auto}.innome-app-mat2__grid{display:grid;grid-template-columns:0.85fr 1.15fr;gap:28px;align-items:stretch}.innome-app-mat2__card{background:#fff;border:1px solid rgba(15,47,58,0.08);border-radius:24px;padding:28px;box-shadow:0 14px 34px rgba(15,47,58,0.05);height:100%}.innome-app-mat2__title{margin:0 0 18px;color:#009FE3;font-size:36px;font-weight:600;letter-spacing:-0.03em}.innome-app-mat2__subtitle{margin:0 0 22px;color:#5d7680;font-size:16px;line-height:1.7}.innome-app-mat2__list{list-style:none;margin:0;padding:0;display:flex;flex-direction:column;gap:10px}.innome-app-mat2__list li{position:relative;padding-left:20px;font-size:16px;line-height:1.6;color:#0f2f3a;font-weight:500}.innome-app-mat2__list li::before{content:\"\";position:absolute;left:0;top:10px;width:8px;height:8px;background:#009FE3;transform:rotate(45deg);border-radius:2px}.innome-app-mat2__list strong{font-weight:600}.innome-oem__links{display:flex;flex-direction:column;gap:12px;margin-top:8px}.innome-oem__link{display:inline-flex;align-items:center;gap:10px;font-size:15px;text-decoration:none;color:#0f2f3a;font-weight:500;transition:all .25s}.innome-oem__link:hover{color:#009FE3}.innome-oem__arrow{color:#009FE3;font-weight:600}@media(max-width:1100px){.innome-app-mat2__grid{grid-template-columns:1fr}}\n<\/style>\n<div class=\"innome-app-mat2__container\">\n<div class=\"innome-app-mat2__grid\">\n \n<div class=\"innome-app-mat2__card\">\n<h2 class=\"innome-app-mat2__title\">Applications<\/h2>\n<p class=\"innome-app-mat2__subtitle\">Wherever UV\/VIS measurements need to be precise, fast and cost-effective:<\/p>\n<ul class=\"innome-app-mat2__list\">\n<li><strong>Protein quantification<\/strong> (A\u2082\u2088\u2080) at high concentrations<\/li>\n<li><strong>DNA\/RNA quantification<\/strong> (A\u2082\u2086\u2080) - direct, without dilution<\/li>\n<li><strong>Protein purity<\/strong> (A\u2082\u2088\u2080\/A\u2082\u2083\u2080 ratio)<\/li>\n<li><strong>Drug Discovery<\/strong> - Drug absorption at 220-300 nm<\/li>\n<li><strong>Enzyme kinetics<\/strong> in the UV range (samples containing DMSO)<\/li>\n<li><strong>Quality control<\/strong> in Biotech &amp; Pharma<\/li>\n<li><strong>Process analytics<\/strong> - High number of samples, fast throughput<\/li>\n<\/ul>\n<\/div>\n \n<div class=\"innome-app-mat2__card\">\n<h2 class=\"innome-app-mat2__title\">Further links<\/h2>\n<p class=\"innome-app-mat2__subtitle\">More about SpecPlate and related products:<\/p>\n<div class=\"innome-oem__links\">\n<a class=\"innome-oem__link\" href=\"https:\/\/shop.innome.de\/products\/specplate-low-binding-uv-vis?srsltid=AfmBOorSIbSHMDVtbGZs8wmIsMVtoUoRdjZluPIwo2mGFGMPgxzDoh_Y\" target=\"_blank\"><span class=\"innome-oem__arrow\">\u2192<\/span>Order SpecPlate - innoME Shop<\/a>\n<a class=\"innome-oem__link\" href=\"https:\/\/phabioc.com\/wp-content\/uploads\/2024\/05\/SpecPlate_Brochure.pdf\" target=\"_blank\"><span class=\"innome-oem__arrow\">\u2192<\/span>Download SpecPlate brochure (PDF)<\/a>\n<a class=\"innome-oem__link\" href=\"https:\/\/phabioc.com\/openinnovation\/specplate\/\" target=\"_blank\"><span class=\"innome-oem__arrow\">\u2192<\/span>Scientific background - Phabioc Open Innovation<\/a>\n<a class=\"innome-oem__link\" href=\"\/uv-vis-spektroskopie-platten\"><span class=\"innome-oem__arrow\">\u2192<\/span>Standard UV\/VIS plates - from \u20ac 15.30 (PS &amp; COC)<\/a>\n<a class=\"innome-oem__link\" href=\"\/multiwell-platten-hersteller\"><span class=\"innome-oem__arrow\">\u2192<\/span>Customised panel production - 6 to 1536 well OEM<\/a>\n<a class=\"innome-oem__link\" href=\"\/zellkulturplatten\"><span class=\"innome-oem__arrow\">\u2192<\/span>All cell culture plates - Overview<\/a>\n<\/div>\n<\/div>\n \n<\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"sb-innome-why\">\n<style>\n.sb-innome-why{background:#fff;font-family:Poppins,system-ui,sans-serif}.sb-innome-why *{box-sizing:border-box}.sb-innome-why__container{max-width:1340px;margin:0 auto}.sb-innome-why__title{margin:0 0 42px;font-size:32px;font-weight:600;color:#009FE3;letter-spacing:-0.03em}.sb-innome-why__grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:24px}.sb-innome-why__card{position:relative;background:#fff;border:1px solid #dfe7ec;border-radius:26px;padding:28px 26px;box-shadow:0 12px 30px rgba(15,47,58,.04);overflow:hidden}.sb-innome-why__card::before{content:\"\";position:absolute;top:0;left:0;width:100%;height:3px;background:#009FE3}.sb-innome-why__icon{width:52px;height:52px;border-radius:14px;background:#eef7fc;border:1px solid #cfe8f7;display:flex;align-items:center;justify-content:center;margin-bottom:16px}.sb-innome-why__check{width:22px;height:22px;stroke:#009FE3;fill:none;stroke-width:2.4;stroke-linecap:round;stroke-linejoin:round}.sb-innome-why__heading{margin:0;font-size:17px;font-weight:400;color:#0f2f3a;line-height:1.5}@media(max-width:1100px){.sb-innome-why__grid{grid-template-columns:repeat(2,minmax(0,1fr))}}@media(max-width:640px){.sb-innome-why__grid{grid-template-columns:1fr}}\n<\/style>\n<div class=\"sb-innome-why__container\">\n<h2 class=\"sb-innome-why__title\">Advantages at a glance<\/h2>\n<div class=\"sb-innome-why__grid\">\n<article class=\"sb-innome-why__card\"><div class=\"sb-innome-why__icon\"><svg class=\"sb-innome-why__check\" viewbox=\"0 0 24 24\"><path d=\"M5 13l4 4L19 7\"\/><\/svg><\/div><h3 class=\"sb-innome-why__heading\">Back injection - no meniscus, no measurement error<\/h3><\/article>\n<article class=\"sb-innome-why__card\"><div class=\"sb-innome-why__icon\"><svg class=\"sb-innome-why__check\" viewbox=\"0 0 24 24\"><path d=\"M5 13l4 4L19 7\"\/><\/svg><\/div><h3 class=\"sb-innome-why__heading\">4 layer heights simultaneously - wide concentration range<\/h3><\/article>\n<article class=\"sb-innome-why__card\"><div class=\"sb-innome-why__icon\"><svg class=\"sb-innome-why__check\" viewbox=\"0 0 24 24\"><path d=\"M5 13l4 4L19 7\"\/><\/svg><\/div><h3 class=\"sb-innome-why__heading\">No dilution steps - highly concentrated direct measurement<\/h3><\/article>\n<article class=\"sb-innome-why__card\"><div class=\"sb-innome-why__icon\"><svg class=\"sb-innome-why__check\" viewbox=\"0 0 24 24\"><path d=\"M5 13l4 4L19 7\"\/><\/svg><\/div><h3 class=\"sb-innome-why__heading\">Only 36 \u00b5l - 4\u00d7 less sample volume than standard<\/h3><\/article>\n<article class=\"sb-innome-why__card\"><div class=\"sb-innome-why__icon\"><svg class=\"sb-innome-why__check\" viewbox=\"0 0 24 24\"><path d=\"M5 13l4 4L19 7\"\/><\/svg><\/div><h3 class=\"sb-innome-why__heading\">UV from 220 nm - COC is UV-transparent, PS is not<\/h3><\/article>\n<article class=\"sb-innome-why__card\"><div class=\"sb-innome-why__icon\"><svg class=\"sb-innome-why__check\" viewbox=\"0 0 24 24\"><path d=\"M5 13l4 4L19 7\"\/><\/svg><\/div><h3 class=\"sb-innome-why__heading\">Manufactured by innoME - in Germany, precision injection moulding<\/h3><\/article>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-tech-faq\">\n<style>\n.innome-tech-faq{background:#fff;font-family:Poppins,system-ui,sans-serif}.innome-tech-faq *{box-sizing:border-box}.innome-tech-faq__header{margin-bottom:34px}.innome-tech-faq__title{margin:0;color:#009FE3;font-size:32px;font-weight:600;letter-spacing:-0.04em}.innome-tech-faq__list{display:flex;flex-direction:column;gap:16px}.innome-tech-faq__item{background:#fff;border:1px solid rgba(15,47,58,0.08);border-radius:22px;overflow:hidden;box-shadow:0 14px 34px rgba(15,47,58,0.06)}.innome-tech-faq__trigger{width:100%;border:0;background:#009FE3;cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:24px;padding:22px 28px;text-align:left}.innome-tech-faq__trigger-left{display:flex;align-items:center;gap:18px;min-width:0}.innome-tech-faq__number{flex:0 0 auto;width:44px;height:44px;border-radius:999px;display:inline-flex;align-items:center;justify-content:center;background:#fff;color:#009FE3;font-size:14px;font-weight:700}.innome-tech-faq__question{margin:0;color:#fff;font-size:20px;font-weight:600;letter-spacing:-0.02em}.innome-tech-faq__icon{flex:0 0 auto;position:relative;width:28px;height:28px}.innome-tech-faq__icon::before,.innome-tech-faq__icon::after{content:\"\";position:absolute;left:50%;top:50%;width:22px;height:2px;background:#fff;border-radius:999px;transform:translate(-50%,-50%);transition:transform .25s,opacity .25s}.innome-tech-faq__icon::after{transform:translate(-50%,-50%) rotate(90deg)}.innome-tech-faq__item.active .innome-tech-faq__icon::after{opacity:0}.innome-tech-faq__content{display:grid;grid-template-rows:0fr;transition:grid-template-rows .35s;background:#fff}.innome-tech-faq__item.active .innome-tech-faq__content{grid-template-rows:1fr}.innome-tech-faq__content-inner{overflow:hidden}.innome-tech-faq__content-wrap{padding:22px 28px 26px}.innome-tech-faq__text{margin:0;color:#0f2f3a;font-size:16px;line-height:1.72;max-width:1100px}.innome-tech-faq__text strong{font-weight:700}@media(max-width:640px){.innome-tech-faq__question{font-size:16px}.innome-tech-faq__trigger{padding:18px}}\n<\/style>\n<div class=\"innome-tech-faq__header\"><h2 class=\"innome-tech-faq__title\">FAQ - SpecPlate<\/h2><\/div>\n<div class=\"innome-tech-faq__list\">\n \n<div class=\"innome-tech-faq__item active\">\n<button class=\"innome-tech-faq__trigger\" type=\"button\" aria-expanded=\"true\">\n<span class=\"innome-tech-faq__trigger-left\"><span class=\"innome-tech-faq__number\">01<\/span><h3 class=\"innome-tech-faq__question\">What does \u201eback injection moulding\u201c mean with the SpecPlate?<\/h3><\/span>\n<span class=\"innome-tech-faq__icon\" aria-hidden=\"true\"><\/span>\n<\/button>\n<div class=\"innome-tech-faq__content\"><div class=\"innome-tech-faq__content-inner\"><div class=\"innome-tech-faq__content-wrap\">\n<p class=\"innome-tech-faq__text\">\u201eBack injection\u201c means that the sample is injected over a single <strong>Inlet channel pressed into the 4 measuring chambers from behind<\/strong> becomes. The sample flows through the cascaded chambers (2000 \u00b5m \u2192 1400 \u00b5m \u2192 700 \u00b5m \u2192 100 \u00b5m) and rises in the inlet and outlet as communicating level vessels. The measuring chambers are filled completely and bubble-free - without a liquid meniscus on the light transmission surface. This eliminates the largest measurement error in standard microtitre plates.<\/p>\n<\/div><\/div><\/div>\n<\/div>\n \n<div class=\"innome-tech-faq__item\">\n<button class=\"innome-tech-faq__trigger\" type=\"button\" aria-expanded=\"false\">\n<span class=\"innome-tech-faq__trigger-left\"><span class=\"innome-tech-faq__number\">02<\/span><h3 class=\"innome-tech-faq__question\">Why do I no longer need dilution steps?<\/h3><\/span>\n<span class=\"innome-tech-faq__icon\" aria-hidden=\"true\"><\/span>\n<\/button>\n<div class=\"innome-tech-faq__content\"><div class=\"innome-tech-faq__content-inner\"><div class=\"innome-tech-faq__content-wrap\">\n<p class=\"innome-tech-faq__text\">In standard plates there is only one layer height (~1 cm). If the sample is too concentrated, the detector saturates - you have to dilute and measure again. The SpecPlate has <strong>4 physically different layer heights (100-2000 \u00b5m) in the same well<\/strong>. Highly concentrated samples are in the detection range in the 100 \u00b5m chamber - at the same time, lower concentrations are precisely measured in the 2000 \u00b5m chamber. No dilution, no error, no extra work.<\/p>\n<\/div><\/div><\/div>\n<\/div>\n \n<div class=\"innome-tech-faq__item\">\n<button class=\"innome-tech-faq__trigger\" type=\"button\" aria-expanded=\"false\">\n<span class=\"innome-tech-faq__trigger-left\"><span class=\"innome-tech-faq__number\">03<\/span><h3 class=\"innome-tech-faq__question\">Does the SpecPlate work with my existing disc reader?<\/h3><\/span>\n<span class=\"innome-tech-faq__icon\" aria-hidden=\"true\"><\/span>\n<\/button>\n<div class=\"innome-tech-faq__content\"><div class=\"innome-tech-faq__content-inner\"><div class=\"innome-tech-faq__content-wrap\">\n<p class=\"innome-tech-faq__text\">Yes - the SpecPlate is <strong>ANSI\/SLAS-compliant<\/strong> and is used with a standard <strong>384-well disc reader<\/strong> (the 4 chambers \u00d7 96 wells = 384 read positions). Compatible with Tecan, BioTek, PerkinElmer, BMG Labtech, Molecular Devices and all other 384-well-capable devices. It is filled like a normal 96-well plate - pipetting robots work without adaptation.<\/p>\n<\/div><\/div><\/div>\n<\/div>\n \n<div class=\"innome-tech-faq__item\">\n<button class=\"innome-tech-faq__trigger\" type=\"button\" aria-expanded=\"false\">\n<span class=\"innome-tech-faq__trigger-left\"><span class=\"innome-tech-faq__number\">04<\/span><h3 class=\"innome-tech-faq__question\">What is the slope method and how do I use it?<\/h3><\/span>\n<span class=\"innome-tech-faq__icon\" aria-hidden=\"true\"><\/span>\n<\/button>\n<div class=\"innome-tech-faq__content\"><div class=\"innome-tech-faq__content-inner\"><div class=\"innome-tech-faq__content-wrap\">\n<p class=\"innome-tech-faq__text\">The 4 layer heights provide 4 absorption values for the same sample. If these are plotted against the layer height (X-axis: \u00b5m, Y-axis: absorbance), a straight line with typical R\u00b2 &gt; 0.999 results. <strong>The gradient of this straight line is proportional to the concentration<\/strong> - according to the Lambert-Beer law (A = \u03b5 \u00d7 c \u00d7 d). This regression analysis significantly increases precision compared to individual measurements and compensates for outliers. Phabioc offers webinars on practical application.<\/p>\n<\/div><\/div><\/div>\n<\/div>\n \n<div class=\"innome-tech-faq__item\">\n<button class=\"innome-tech-faq__trigger\" type=\"button\" aria-expanded=\"false\">\n<span class=\"innome-tech-faq__trigger-left\"><span class=\"innome-tech-faq__number\">05<\/span><h3 class=\"innome-tech-faq__question\">Where can I buy the SpecPlate?<\/h3><\/span>\n<span class=\"innome-tech-faq__icon\" aria-hidden=\"true\"><\/span>\n<\/button>\n<div class=\"innome-tech-faq__content\"><div class=\"innome-tech-faq__content-inner\"><div class=\"innome-tech-faq__content-wrap\">\n<p class=\"innome-tech-faq__text\">The SpecPlate (Art. 400100, 40 pieces\/box) is available directly in the <strong>innoME Shop<\/strong> available: <a href=\"https:\/\/shop.innome.de\/products\/specplate-low-binding-uv-vis?srsltid=AfmBOorSIbSHMDVtbGZs8wmIsMVtoUoRdjZluPIwo2mGFGMPgxzDoh_Y\">shop.innome.de<\/a>. For larger quantities, OEM enquiries or special conditions, please contact the <strong>innoME GmbH<\/strong> as a manufacturer.<\/p>\n<\/div><\/div><\/div>\n<\/div>\n \n<\/div>\n<script>\n(function(){\nconst section = document.querySelector('.innome-tech-faq');\nif(!section) return;\nconst items = section.querySelectorAll('.innome-tech-faq__item');\nitems.forEach(item => {\nconst trigger = item.querySelector('.innome-tech-faq__trigger');\ntrigger.addEventListener('click', () => {\nconst isActive = item.classList.contains('active');\nitems.forEach(other => { other.classList.remove('active'); other.querySelector('.innome-tech-faq__trigger')?.setAttribute('aria-expanded','false'); });\nif(!isActive){ item.classList.add('active'); trigger.setAttribute('aria-expanded','true'); }\n});\n});\n})();\n<\/script>\n<\/section>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>SpecPlate \u2013 Der bessere Standard f\u00fcr plattenbasierte UV\/VIS-Spektroskopie | 4 Messkammern, Hinterspritzen-Prinzip Revolution\u00e4re 96-Well Platte mit 4 physikalischen Schichth\u00f6hen (100\u20132000 \u00b5m) \u2013 misst hochkonzentrierte Proben ohne Verd\u00fcnnungsschritte, eliminiert Meniskusprobleme, nur [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_EventAllDay":false,"_EventTimezone":"","_EventStartDate":"","_EventEndDate":"","_EventStartDateUTC":"","_EventEndDateUTC":"","_EventShowMap":false,"_EventShowMapLink":false,"_EventURL":"","_EventCost":"","_EventCostDescription":"","_EventCurrencySymbol":"","_EventCurrencyCode":"","_EventCurrencyPosition":"","_EventDateTimeSeparator":"","_EventTimeRangeSeparator":"","_EventOrganizerID":[],"_EventVenueID":[],"_OrganizerEmail":"","_OrganizerPhone":"","_OrganizerWebsite":"","_VenueAddress":"","_VenueCity":"","_VenueCountry":"","_VenueProvince":"","_VenueState":"","_VenueZip":"","_VenuePhone":"","_VenueURL":"","_VenueStateProvince":"","_VenueLat":"","_VenueLng":"","_VenueShowMap":false,"_VenueShowMapLink":false,"footnotes":""},"class_list":["post-1421","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SpecPlate kaufen \u2013 4 Messkammern, kein Meniskus | innoME<\/title>\n<meta name=\"description\" content=\"SpecPlate von innoME \u2013 96-Well UV\/VIS Platte mit 4 Schichth\u00f6hen (100\u20132000 \u00b5m), Hinterspritzen-Prinzip, nur 36 \u00b5l, keine Verd\u00fcnnung. innoME.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/innome.de\/en\/specplate\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SpecPlate kaufen \u2013 4 Messkammern, kein Meniskus | innoME\" \/>\n<meta property=\"og:description\" content=\"SpecPlate von innoME \u2013 96-Well UV\/VIS Platte mit 4 Schichth\u00f6hen (100\u20132000 \u00b5m), Hinterspritzen-Prinzip, nur 36 \u00b5l, keine Verd\u00fcnnung. innoME.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/innome.de\/en\/specplate\/\" \/>\n<meta property=\"og:site_name\" content=\"innome\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-05T09:13:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1368\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innome.de\\\/specplate\\\/\",\"url\":\"https:\\\/\\\/innome.de\\\/specplate\\\/\",\"name\":\"SpecPlate kaufen \u2013 4 Messkammern, kein Meniskus | innoME\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innome.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/innome.de\\\/specplate\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/innome.de\\\/specplate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/362623.jpg\",\"datePublished\":\"2026-05-05T09:13:32+00:00\",\"dateModified\":\"2026-05-05T09:13:33+00:00\",\"description\":\"SpecPlate von innoME \u2013 96-Well UV\\\/VIS Platte mit 4 Schichth\u00f6hen (100\u20132000 \u00b5m), Hinterspritzen-Prinzip, nur 36 \u00b5l, keine Verd\u00fcnnung. innoME.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innome.de\\\/specplate\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/innome.de\\\/specplate\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/innome.de\\\/specplate\\\/#primaryimage\",\"url\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/362623.jpg\",\"contentUrl\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/362623.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innome.de\\\/specplate\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innome.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SpecPlate\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innome.de\\\/#website\",\"url\":\"https:\\\/\\\/innome.de\\\/\",\"name\":\"innome\",\"description\":\"Lab consumable and live cell imaging supplier\",\"publisher\":{\"@id\":\"https:\\\/\\\/innome.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/innome.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innome.de\\\/#organization\",\"name\":\"innome\",\"url\":\"https:\\\/\\\/innome.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/innome.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/innoMEPNG.png\",\"contentUrl\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/innoMEPNG.png\",\"width\":125,\"height\":26,\"caption\":\"innome\"},\"image\":{\"@id\":\"https:\\\/\\\/innome.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Buy SpecPlate - 4 measuring chambers, no meniscus | innoME","description":"SpecPlate from innoME - 96-well UV\/VIS plate with 4 layer heights (100-2000 \u00b5m), back-spraying principle, only 36 \u00b5l, no dilution. innoME.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/innome.de\/en\/specplate\/","og_locale":"en_GB","og_type":"article","og_title":"SpecPlate kaufen \u2013 4 Messkammern, kein Meniskus | innoME","og_description":"SpecPlate von innoME \u2013 96-Well UV\/VIS Platte mit 4 Schichth\u00f6hen (100\u20132000 \u00b5m), Hinterspritzen-Prinzip, nur 36 \u00b5l, keine Verd\u00fcnnung. innoME.","og_url":"https:\/\/innome.de\/en\/specplate\/","og_site_name":"innome","article_modified_time":"2026-05-05T09:13:33+00:00","og_image":[{"width":1920,"height":1368,"url":"https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/innome.de\/specplate\/","url":"https:\/\/innome.de\/specplate\/","name":"Buy SpecPlate - 4 measuring chambers, no meniscus | innoME","isPartOf":{"@id":"https:\/\/innome.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/innome.de\/specplate\/#primaryimage"},"image":{"@id":"https:\/\/innome.de\/specplate\/#primaryimage"},"thumbnailUrl":"https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623.jpg","datePublished":"2026-05-05T09:13:32+00:00","dateModified":"2026-05-05T09:13:33+00:00","description":"SpecPlate from innoME - 96-well UV\/VIS plate with 4 layer heights (100-2000 \u00b5m), back-spraying principle, only 36 \u00b5l, no dilution. innoME.","breadcrumb":{"@id":"https:\/\/innome.de\/specplate\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/innome.de\/specplate\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/innome.de\/specplate\/#primaryimage","url":"https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623.jpg","contentUrl":"https:\/\/innome.de\/wp-content\/uploads\/2026\/03\/362623.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/innome.de\/specplate\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/innome.de\/"},{"@type":"ListItem","position":2,"name":"SpecPlate"}]},{"@type":"WebSite","@id":"https:\/\/innome.de\/#website","url":"https:\/\/innome.de\/","name":"innome","description":"Laboratory consumables and live cell imaging supplier","publisher":{"@id":"https:\/\/innome.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/innome.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/innome.de\/#organization","name":"innome","url":"https:\/\/innome.de\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/innome.de\/#\/schema\/logo\/image\/","url":"https:\/\/innome.de\/wp-content\/uploads\/2026\/02\/innoMEPNG.png","contentUrl":"https:\/\/innome.de\/wp-content\/uploads\/2026\/02\/innoMEPNG.png","width":125,"height":26,"caption":"innome"},"image":{"@id":"https:\/\/innome.de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/pages\/1421","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/comments?post=1421"}],"version-history":[{"count":3,"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/pages\/1421\/revisions"}],"predecessor-version":[{"id":1424,"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/pages\/1421\/revisions\/1424"}],"wp:attachment":[{"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/media?parent=1421"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}