{"id":1626,"date":"2026-05-27T14:37:23","date_gmt":"2026-05-27T14:37:23","guid":{"rendered":"https:\/\/innome.de\/?page_id=1626"},"modified":"2026-05-27T14:37:25","modified_gmt":"2026-05-27T14:37:25","slug":"nanodrop-alternative-specplate","status":"publish","type":"page","link":"https:\/\/innome.de\/en\/nanodrop-alternative-specplate\/","title":{"rendered":"NanoDrop Alternative SpecPlate"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-global-padding is-content-justification-center is-layout-constrained wp-container-core-group-is-layout-b6632178 wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--28);margin-bottom:var(--wp--preset--spacing--28);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--16);padding-left:var(--wp--preset--spacing--16);flex-basis:100%\">\n<div class=\"wp-block-group has-global-padding is-content-justification-center is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-left\">NanoDrop Alternative \u2013 SpecPlate for High-Throughput UV\/Vis Quantification<\/h2>\n\n\n\n<p class=\"has-text-align-left\"><strong>Measure 96 samples simultaneously in a microplate reader\u2014without expensive specialized equipment and without dilution<\/strong><\/p>\n\n\n\n<p class=\" translation-block\">As the number of samples increases, sequential measurements on the NanoDrop reach their structural limits. The <strong>SpecPlate<\/strong> measures all 96 samples in parallel in the UV\/Vis range\u2014using the plate reader already available in your lab.<\/p>\n\n\n\n<p class=\" translation-block\">Developed as a <strong>KIT spin-off<\/strong>, manufactured and distributed by <strong>innoME GmbH<\/strong>: patented measurement chamber technology eliminates meniscus errors, provides 4 independent measurement points per sample, and reduces consumables by up to 75%.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50\"><a class=\"wp-block-button__link wp-element-button\" href=\"#vergleich\" style=\"border-top-left-radius:100px;border-top-right-radius:100px;border-bottom-left-radius:100px;border-bottom-right-radius:100px\">View direct comparison<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--16);padding-left:var(--wp--preset--spacing--16);flex-basis:100%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized has-custom-border\"><img fetchpriority=\"high\" decoding=\"async\" width=\"2560\" height=\"1978\" src=\"https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg\" alt=\"SpecPlate UV\/Vis Mikroplatte als NanoDrop Alternative \u2013 96-Well COC Platte f\u00fcr Hochdurchsatz-Quantifizierung von DNA, RNA und Proteinen\" class=\"wp-image-1628\" style=\"border-style:none;border-width:0px;border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-left-radius:10px;border-bottom-right-radius:10px;object-fit:cover;width:400px;height:300px\" srcset=\"https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg 2560w, https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-300x232.jpg 300w, https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-1024x791.jpg 1024w, https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-768x593.jpg 768w, https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-1536x1187.jpg 1536w, https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-2048x1583.jpg 2048w, https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-16x12.jpg 16w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-specs-grid\">\n<style>\n.innome-specs-grid{ background:#ffffff; font-family:Poppins,system-ui,-apple-system,sans-serif; }\n.innome-specs-grid *{ box-sizing:border-box; }\n.innome-specs-grid__container{ max-width:1340px; margin:0 auto; }\n.innome-specs-grid__title{ margin:0 0 28px; color:#009FE3; font-size:42px; line-height:1.05; font-weight:600; letter-spacing:-0.03em; }\n.innome-specs-grid__grid{ display:grid; grid-template-columns:repeat(4,minmax(0,1fr)); gap:22px; }\n.innome-specs-grid__item{ border:1px solid rgba(15,47,58,0.08); border-radius:18px; padding:22px; transition:border-color .25s,box-shadow .25s,transform .25s; }\n.innome-specs-grid__item:hover{ border-color:rgba(0,159,227,0.25); box-shadow:0 12px 30px rgba(15,47,58,0.08); transform:translateY(-2px); }\n.innome-specs-grid__label{ margin:0 0 6px; color:#0f2f3a; font-size:17px; font-weight:600; }\n.innome-specs-grid__value{ margin:0; color:#5d7680; font-size:15px; line-height:1.65; }\n@media(max-width:1000px){ .innome-specs-grid__grid{ grid-template-columns:repeat(2,1fr); } }\n@media(max-width:640px){ .innome-specs-grid__grid{ grid-template-columns:1fr; } }\n<\/style>\n<div class=\"innome-specs-grid__container\">\n<h2 class=\"innome-specs-grid__title\">The most common limitations of the NanoDrop<\/h2>\n<div class=\"innome-specs-grid__grid\">\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Sequential throughput<\/h3><p class=\"innome-specs-grid__value\">Each sample is measured individually. For 96 samples, the measurement process alone takes 30\u201360 minutes, not including setup and cleanup.<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Propriet\u00e4res Instrument<\/h3><p class=\"innome-specs-grid__value\">The NanoDrop is a dedicated instrument with a purchase price of \u20ac8,000\u2013\u20ac15,000. Each location requires its own instrument.<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Not high-throughput<\/h3><p class=\"innome-specs-grid__value\">The system is not designed for NGS sample preparation, biobank quality control, or screening involving several hundred samples per day.<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Limited automation<\/h3><p class=\"innome-specs-grid__value\">Manual sample loading at the pedestal is difficult to automate. Integration with liquid handlers requires special models.<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Open system<\/h3><p class=\"innome-specs-grid__value\">The open pedestal requires careful cleaning. Evaporation and residual samples can skew subsequent measurements.<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">No economies of scale<\/h3><p class=\"innome-specs-grid__value\">The cost per measurement does not decrease as sample throughput increases. In high-volume workflows, there is no economic benefit.<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Measurement time: 96 samples<\/h3><p class=\"innome-specs-grid__value\">40\u201360 minutes of pure measurement time on the NanoDrop vs. 5\u201310 minutes with SpecPlate in a microplate reader.<\/p><\/div>\n<div class=\"innome-specs-grid__item\"><h3 class=\"innome-specs-grid__label\">Data points per sample<\/h3><p class=\"innome-specs-grid__value\">NanoDrop: 1 measurement per sample. SpecPlate: 4 independent measurement chambers per well.<\/p><\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-app-mat\">\n<style>\n.innome-app-mat{ background:#fff; font-family:Poppins,system-ui,-apple-system,sans-serif; }\n.innome-app-mat *{ box-sizing:border-box; }\n.innome-app-mat__container{ max-width:1340px; margin:0 auto; }\n.innome-app-mat__title{ margin:0 0 18px; color:#009FE3; font-size:40px; line-height:1.05; font-weight:600; letter-spacing:-0.03em; }\n.innome-app-mat__subtitle{ margin:0 0 22px; color:#5d7680; font-size:17px; line-height:1.7; }\n.innome-app-mat__grid{ display:grid; grid-template-columns:0.85fr 1.15fr; gap:28px; align-items:stretch; }\n.innome-app-mat__card{ background:#ffffff; border:1px solid rgba(15,47,58,0.08); border-radius:24px; padding:28px; box-shadow:0 14px 34px rgba(15,47,58,0.05); height:100%; }\n.innome-app-mat__list{ list-style:none; margin:0; padding:0; display:flex; flex-direction:column; gap:12px; }\n.innome-app-mat__list li{ position:relative; padding-left:20px; font-size:17px; line-height:1.6; color:#0f2f3a; font-weight:500; }\n.innome-app-mat__list li::before{ content:\"\"; position:absolute; left:0; top:10px; width:8px; height:8px; background:#009FE3; transform:rotate(45deg); border-radius:2px; }\n.innome-app-mat__list strong{ font-weight:600; }\n.innome-app-mat__table-wrap{ overflow-x:auto; border:1px solid rgba(15,47,58,0.08); border-radius:18px; }\n.innome-app-mat__table{ width:100%; border-collapse:collapse; }\n.innome-app-mat__table th,.innome-app-mat__table td{ padding:14px 18px; text-align:left; border-bottom:1px solid rgba(15,47,58,0.08); border-right:1px solid rgba(15,47,58,0.08); font-size:14px; }\n.innome-app-mat__table th:last-child,.innome-app-mat__table td:last-child{ border-right:none; }\n.innome-app-mat__table tr:last-child td{ border-bottom:none; }\n.innome-app-mat__table thead th{ background:rgba(0,159,227,0.06); color:#009FE3; font-weight:600; }\n.innome-app-mat__table tbody td:first-child{ font-weight:600; color:#0f2f3a; }\n.innome-app-mat__table tbody td:not(:first-child){ color:#5d7680; }\n.innome-app-mat__tag{ display:inline-block; background:#009FE3; color:#fff; font-size:10px; font-weight:600; letter-spacing:.06em; text-transform:uppercase; padding:2px 8px; border-radius:100px; margin-left:6px; vertical-align:middle; }\n@media(max-width:1100px){ .innome-app-mat__grid{ grid-template-columns:1fr; } }\n<\/style>\n<div class=\"innome-app-mat__container\">\n<h2 class=\"innome-app-mat__title\" id=\"vergleich\">NanoDrop vs. SpecPlate \u2013 A Direct Comparison<\/h2>\n<p class=\"innome-app-mat__subtitle\">A direct comparison of all three systems based on the most important criteria:<\/p>\n<div class=\"innome-app-mat__grid\">\n<div class=\"innome-app-mat__card\">\n<h2 class=\"innome-app-mat__title\" style=\"font-size:28px;\">Suitable for SpecPlate<\/h2>\n<p class=\"innome-app-mat__subtitle\">Anywhere where the number of samples and time constraints increase.<\/p>\n<ul class=\"innome-app-mat__list\">\n<li><strong>NGS-sample preparation<\/strong> - QC for 96+ samples<\/li>\n<li><strong>Biopharmaceutical QC<\/strong> \u2013 mAb, Enzyme, antibody<\/li>\n<li><strong>bio bank<\/strong> \u2013 Routine inspection of large collections<\/li>\n<li><strong>CRO \/ DMPK<\/strong> \u2013 flexible, automatable workflows<\/li>\n<li><strong>ATMP producer<\/strong> \u2013 regulatory compliance<\/li>\n<li class=\" translation-block\"><strong>Diagnostics<\/strong> \u2013 High-Throughput QC<\/li>\n<\/ul>\n<\/div>\n<div class=\"innome-app-mat__card\">\n<h2 class=\"innome-app-mat__title\" style=\"font-size:28px;\">Comparison Table<\/h2>\n<div class=\"innome-app-mat__table-wrap\">\n<table class=\"innome-app-mat__table\">\n<thead><tr><th>Criteria<\/th><th>NanoDrop One<\/th><th>SpecPlate<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Measurement format<\/td><td>Individually, sequentially<\/td><td>96 samples in parallel <span class=\"innome-app-mat__tag\">Benefit<\/span><\/td><\/tr>\n<tr><td>Sample quantity<\/td><td>1\u20132 \u00b5l<\/td><td>36 \u00b5l<\/td><\/tr>\n<tr><td>Measurement time: 96 samples<\/td><td>40 - 60 minutes<\/td><td>5 - 10 minutes <span class=\"innome-app-mat__tag\">\u201385%<\/span><\/td><\/tr>\n<tr><td>Instrument<\/td><td>8.000\u201315.000 \u20ac<\/td><td>Available Plate reader <span class=\"innome-app-mat__tag\">Benefit<\/span><\/td><\/tr>\n<tr><td>Meniscus defect<\/td><td>Possible<\/td><td>Eliminated <span class=\"innome-app-mat__tag\">Benefit<\/span><\/td><\/tr>\n<tr><td>Data set \/ Sample<\/td><td>1<\/td><td>4 measurement chambers <span class=\"innome-app-mat__tag\">Benefit<\/span><\/td><\/tr>\n<tr><td>SLAS \/ Automation<\/td><td>Limited<\/td><td>Complete <span class=\"innome-app-mat__tag\">Benefit<\/span><\/td><\/tr>\n<tr><td>Ongoing equipment costs<\/td><td>Maintenance, Service<\/td><td>Disposable plate only<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-plattenleser\">\n<style>\n.innome-plattenleser{ background:#ffffff; font-family:Poppins,system-ui,-apple-system,sans-serif; }\n.innome-plattenleser *{ box-sizing:border-box; }\n.innome-plattenleser__container{ max-width:1340px; margin:0 auto; }\n.innome-plattenleser__title{ margin:0 0 14px; color:#009FE3; font-size:42px; line-height:1.05; font-weight:600; letter-spacing:-0.03em; }\n.innome-plattenleser__subtitle{ margin:0 0 32px; color:#5d7680; font-size:17px; line-height:1.7; max-width:700px; }\n.innome-plattenleser__grid{ display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:22px; }\n.innome-plattenleser__item{ border:1px solid rgba(15,47,58,0.08); border-radius:18px; padding:22px; transition:border-color .25s,box-shadow .25s,transform .25s; }\n.innome-plattenleser__item:hover{ border-color:rgba(0,159,227,0.25); box-shadow:0 12px 30px rgba(15,47,58,0.08); transform:translateY(-2px); }\n.innome-plattenleser__label{ margin:0 0 8px; color:#0f2f3a; font-size:17px; font-weight:600; }\n.innome-plattenleser__value{ margin:0; color:#5d7680; font-size:14px; line-height:1.65; }\n@media(max-width:1000px){ .innome-plattenleser__grid{ grid-template-columns:repeat(2,1fr); } }\n@media(max-width:640px){ .innome-plattenleser__grid{ grid-template-columns:1fr; } }\n<\/style>\n<div class=\"innome-plattenleser__container\">\n<h2 class=\"innome-plattenleser__title\">Compatible plate reader<\/h2>\n<p class=\"innome-plattenleser__subtitle\">SpecPlate is compatible with any UV\/Vis microplate reader that supports the standard 96-well SBS\/SLAS format and measures in the 230\u2013800 nm range:<\/p>\n<div class=\"innome-plattenleser__grid\">\n<div class=\"innome-plattenleser__item\"><h3 class=\"innome-plattenleser__label\">BMG Labtech<\/h3><p class=\"innome-plattenleser__value\">SPECTROstar Nano, SPECTROstar Omega, CLARIOstar Plus, VANTAstar, PHERAstar FSX<br><br>Full spectrum 220\u20131000 nm, &lt;1 sec\/well.<\/p><\/div>\n<div class=\"innome-plattenleser__item\"><h3 class=\"innome-plattenleser__label\">Molecular Devices<\/h3><p class=\"innome-plattenleser__value\">SpectraMax ABS Plus, SpectraMax i3x, SpectraMax M2\/M4\/M5<br><br>190\u20131000 nm, 96\u2013384 Well.<\/p><\/div>\n<div class=\"innome-plattenleser__item\"><h3 class=\"innome-plattenleser__label\">Agilent \/ BioTek<\/h3><p class=\"innome-plattenleser__value\">Epoch 2, Synergy H1, Synergy Neo2, Cytation 5<br><br>Widespread adoption in Germany.<\/p><\/div>\n<div class=\"innome-plattenleser__item\"><h3 class=\"innome-plattenleser__label\">Tecan<\/h3><p class=\"innome-plattenleser__value\">Spark, Infinite 200 PRO, Infinite F Nano<br><br>Standard practice at many German research institutions.<\/p><\/div>\n<div class=\"innome-plattenleser__item\"><h3 class=\"innome-plattenleser__label\">Thermo Fisher<\/h3><p class=\"innome-plattenleser__value\">Varioskan LUX, Multiskan SkyHigh, Multiskan FC<br><br>200\u20131,000 nm, proven in academic and clinical laboratories.<\/p><\/div>\n<div class=\"innome-plattenleser__item\"><h3 class=\"innome-plattenleser__label\">Not sure?<\/h3><p class=\"innome-plattenleser__value\">Please contact us with the model of your disc drive. We'll check compatibility for free.<br><br><a href=\"mailto:info@innome.de\" style=\"color:#009FE3;font-weight:600;\">\u2192 info@innome.de<\/a><\/p><\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-preis\">\n<style>\n.innome-preis{ background:#ffffff; font-family:Poppins,system-ui,-apple-system,sans-serif; }\n.innome-preis *{ box-sizing:border-box; }\n.innome-preis__container{ max-width:1340px; margin:0 auto; }\n.innome-preis__grid{ display:grid; grid-template-columns:0.85fr 1.15fr; gap:28px; align-items:stretch; }\n.innome-preis__card{ background:#ffffff; border:1px solid rgba(15,47,58,0.08); border-radius:24px; padding:28px; box-shadow:0 14px 34px rgba(15,47,58,0.05); height:100%; }\n.innome-preis__title{ margin:0 0 12px; color:#009FE3; font-size:32px; line-height:1.05; font-weight:600; letter-spacing:-0.03em; }\n.innome-preis__subtitle{ margin:0 0 20px; color:#5d7680; font-size:15px; line-height:1.7; }\n.innome-preis__list{ list-style:none; margin:0; padding:0; display:flex; flex-direction:column; gap:12px; }\n.innome-preis__list li{ position:relative; padding-left:20px; font-size:15px; line-height:1.6; color:#0f2f3a; font-weight:500; }\n.innome-preis__list li::before{ content:\"\"; position:absolute; left:0; top:9px; width:8px; height:8px; background:#009FE3; transform:rotate(45deg); border-radius:2px; }\n.innome-preis__list strong{ font-weight:600; }\n.innome-preis__table-wrap{ overflow-x:auto; border:1px solid rgba(15,47,58,0.08); border-radius:18px; }\n.innome-preis__table{ width:100%; border-collapse:collapse; }\n.innome-preis__table th,.innome-preis__table td{ padding:14px 18px; text-align:left; border-bottom:1px solid rgba(15,47,58,0.08); border-right:1px solid rgba(15,47,58,0.08); font-size:14px; }\n.innome-preis__table th:last-child,.innome-preis__table td:last-child{ border-right:none; }\n.innome-preis__table tr:last-child td{ border-bottom:none; }\n.innome-preis__table thead th{ background:rgba(0,159,227,0.06); color:#009FE3; font-weight:600; }\n.innome-preis__table tbody td:first-child{ font-weight:600; color:#0f2f3a; }\n.innome-preis__table tbody td:not(:first-child){ color:#5d7680; }\n.innome-preis__cta{ margin-top:22px; padding:22px 24px; border:1px solid rgba(0,159,227,0.25); border-radius:18px; background:rgba(0,159,227,0.04); display:flex; align-items:center; justify-content:space-between; gap:20px; flex-wrap:wrap; }\n.innome-preis__cta p{ margin:0; }\n.innome-preis__cta-title{ font-size:15px; font-weight:600; color:#0f2f3a; margin-bottom:4px !important; }\n.innome-preis__cta-sub{ font-size:13px; color:#5d7680; }\n@media(max-width:1100px){ .innome-preis__grid{ grid-template-columns:1fr; } }\n<\/style>\n<div class=\"innome-preis__container\">\n<div class=\"innome-preis__grid\">\n<div class=\"innome-preis__card\">\n<h2 class=\"innome-preis__title\">Price estimate<\/h2>\n<p class=\"innome-preis__subtitle\">SpecPlate is designed as a disposable plate\u2014no need to purchase instruments, no service fees.<\/p>\n<ul class=\"innome-preis__list\">\n<li><strong>One plate:<\/strong> Price on application<\/li>\n<li><strong>Volume discounts<\/strong> 10 or more plates<\/li>\n<li><strong>Sample<\/strong> free of charge upon request<\/li>\n<li><strong>Delivery<\/strong> from German warehouse<\/li>\n<li><strong>Payment:<\/strong> Invoice within 30 days net<\/li>\n<\/ul>\n<\/div>\n<div class=\"innome-preis__card\">\n<h2 class=\"innome-preis__title\">Cost Comparison<\/h2>\n<div class=\"innome-preis__table-wrap\">\n<table class=\"innome-preis__table\">\n<thead><tr><th>Cost<\/th><th>NanoDrop<\/th><th>SpecPlate<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Instrument<\/td><td>8.000\u201315.000 \u20ac<\/td><td>\u20ac0 (pre-owned device)<\/td><\/tr>\n<tr><td>Service Contract\/Year<\/td><td>800\u20132.000 \u20ac<\/td><td>0 \u20ac<\/td><\/tr>\n<tr><td>Consumables<\/td><td>Propriet\u00e4r<\/td><td>Open market<\/td><\/tr>\n<tr><td>Costs\/Measurement<\/td><td>Does not scale<\/td><td>Volume discount<\/td><\/tr>\n<tr><td>Entry barrier<\/td><td>High<\/td><td>None<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"innome-preis__cta\">\n<div>\n<p class=\"innome-preis__cta-title\">Request a quote or order a sample<\/p>\n<p class=\"innome-preis__cta-sub\">innoME GmbH \u00b7 info@innome.de \u00b7 +49 89 215 377 00<\/p>\n<\/div>\n<a href=\"mailto:info@innome.de\" style=\"display:inline-block;background:#009FE3;color:#fff;padding:12px 28px;border-radius:100px;font-size:15px;font-weight:600;text-decoration:none;\">Request a quote<\/a>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-faq\">\n<style>\n.innome-faq{ background:#ffffff; font-family:Poppins,system-ui,-apple-system,sans-serif; }\n.innome-faq *{ box-sizing:border-box; }\n.innome-faq__container{ max-width:1340px; margin:0 auto; }\n.innome-faq__title{ margin:0 0 32px; color:#009FE3; font-size:42px; line-height:1.05; font-weight:600; letter-spacing:-0.03em; }\n.innome-faq__item{ border-bottom:1px solid rgba(15,47,58,0.08); padding:22px 0; }\n.innome-faq__item:first-of-type{ padding-top:0; }\n.innome-faq__q{ font-size:16px; font-weight:600; color:#0f2f3a; margin:0 0 10px; line-height:1.4; }\n.innome-faq__a{ font-size:15px; color:#5d7680; line-height:1.75; margin:0; }\n.innome-faq__a strong{ color:#0f2f3a; }\n<\/style>\n<div class=\"innome-faq__container\">\n<h2 class=\"innome-faq__title\">Frequently Asked Questions<\/h2>\n<div class=\"innome-faq__item\"><p class=\"innome-faq__q\">Can SpecPlate completely replace the NanoDrop?<\/p><p class=\"innome-faq__a translation-block\">For high-throughput applications involving 24 or more samples, SpecPlate is the more powerful solution. Many laboratories use SpecPlate as <strong>their primary system for batch QC<\/strong> and keep the NanoDrop for ad hoc measurements\u2014or replace it entirely.<\/p><\/div>\n<div class=\"innome-faq__item\"><p class=\"innome-faq__q\">What kind of record player do I need?<\/p><p class=\"innome-faq__a translation-block\">Any UV\/Vis instrument with a measurement range of 230\u2013800 nm and a standard 96-well SBS\/SLAS format. Compatible with <strong>BMG Labtech, Molecular Devices, BioTek\/Agilent, and Tecan<\/strong>. Contact us to verify compatibility.<\/p><\/div>\n<div class=\"innome-faq__item\"><p class=\"innome-faq__q\">How much sample is required?<\/p><p class=\"innome-faq__a translation-block\">SpecPlate requires <strong>36 \u00b5l per sample<\/strong>. The NanoDrop operates with 1\u20132 \u00b5l. When measurement time and automatability are important factors, the advantages of SpecPlate clearly outweigh the disadvantages.<\/p><\/div>\n<div class=\"innome-faq__item\"><p class=\"innome-faq__q\">Is SpecPlate suitable for DNA, RNA, and proteins?<\/p><p class=\"innome-faq__a translation-block\">Yes. <strong>DNA\/RNA at 260 nm<\/strong>, A260\/A280, and <strong>protein at 280 nm or 205 nm<\/strong>. Colorimetric assays such as BCA or Bradford are also possible.<\/p><\/div>\n<div class=\"innome-faq__item\"><p class=\"innome-faq__q\">How much does SpecPlate cost compared to the NanoDrop?<\/p><p class=\"innome-faq__a translation-block\">NanoDrop One: approx. <strong>\u20ac8,000\u201315,000<\/strong> plus ongoing costs. SpecPlate is a <strong>disposable plate with no instrument costs<\/strong>. Contact us for a customized quote.<\/p><\/div>\n<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30);padding-top:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30)\">\n<section class=\"innome-oem\">\n<style>\n.innome-oem{ background:#ffffff; font-family:Poppins,system-ui,-apple-system,sans-serif; }\n.innome-oem *{ box-sizing:border-box; }\n.innome-oem__container{ max-width:1340px; margin:0 auto; }\n.innome-oem__card{ border:1px solid rgba(15,47,58,0.08); border-radius:24px; padding:36px; background:#fff; box-shadow:0 14px 34px rgba(15,47,58,0.05); }\n.innome-oem__title{ margin:0 0 12px; color:#009FE3; font-size:32px; line-height:1.05; font-weight:600; letter-spacing:-0.03em; }\n.innome-oem__subtitle{ margin:0 0 26px; font-size:16px; line-height:1.7; color:#5d7680; }\n.innome-oem__links{ display:flex; flex-direction:column; gap:14px; }\n.innome-oem__link{ display:inline-flex; align-items:center; gap:10px; font-size:16px; text-decoration:none; color:#0f2f3a; font-weight:500; transition:color .25s; }\n.innome-oem__link:hover{ color:#009FE3; }\n.innome-oem__arrow{ color:#009FE3; font-weight:600; }\n<\/style>\n<div class=\"innome-oem__container\">\n<div class=\"innome-oem__card\">\n<h2 class=\"innome-oem__title\">Further comparisons and resources<\/h2>\n<p class=\"innome-oem__subtitle\">All relevant pages about SpecPlate on innome.de:<\/p>\n<div class=\"innome-oem__links\">\n<a class=\"innome-oem__link\" href=\"\/analytik\/specplate\"><span class=\"innome-oem__arrow\">\u2192<\/span>SpecPlate Product Page \u2013 Specifications and Ordering<\/a>\n<a class=\"innome-oem__link\" href=\"\/analytik\/greiner-uv-star-alternative\"><span class=\"innome-oem__arrow\">\u2192<\/span>Greiner UV-Star Alternative \u2013 Standard UV Plate vs. SpecPlate<\/a>\n<a class=\"innome-oem__link\" href=\"\/analytik\/lunatic-alternative\"><span class=\"innome-oem__arrow\">\u2192<\/span>Lunatic Alternative \u2013 Proprietary System vs. SpecPlate<\/a>\n<a class=\"innome-oem__link\" href=\"\/analytik\/uv-vis-methoden-vergleich\"><span class=\"innome-oem__arrow\">\u2192<\/span>Alle UV\/Vis-Quantifizierungsmethoden im Vergleich<\/a>\n<a class=\"innome-oem__link\" href=\"\/blog\/dna-quantifizierung-hochdurchsatz\"><span class=\"innome-oem__arrow\">\u2192<\/span>Blog: High-Throughput DNA Quantification<\/a>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>NanoDrop Alternative \u2013 SpecPlate f\u00fcr High-Throughput UV\/Vis-Quantifizierung 96 Proben gleichzeitig im Plattenleseger\u00e4t messen \u2013 ohne teures Spezialinstrument, ohne Verd\u00fcnnung Sequenzielle Messungen am NanoDrop sto\u00dfen bei wachsenden Probenzahlen an strukturelle Grenzen. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_EventAllDay":false,"_EventTimezone":"","_EventStartDate":"","_EventEndDate":"","_EventStartDateUTC":"","_EventEndDateUTC":"","_EventShowMap":false,"_EventShowMapLink":false,"_EventURL":"","_EventCost":"","_EventCostDescription":"","_EventCurrencySymbol":"","_EventCurrencyCode":"","_EventCurrencyPosition":"","_EventDateTimeSeparator":"","_EventTimeRangeSeparator":"","_EventOrganizerID":[],"_EventVenueID":[],"_OrganizerEmail":"","_OrganizerPhone":"","_OrganizerWebsite":"","_VenueAddress":"","_VenueCity":"","_VenueCountry":"","_VenueProvince":"","_VenueState":"","_VenueZip":"","_VenuePhone":"","_VenueURL":"","_VenueStateProvince":"","_VenueLat":"","_VenueLng":"","_VenueShowMap":false,"_VenueShowMapLink":false,"footnotes":""},"class_list":["post-1626","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>NanoDrop Alternative \u2013 SpecPlate UV\/Vis | innoME<\/title>\n<meta name=\"description\" content=\"SpecPlate misst 96 Proben parallel im UV\/Vis \u2013 auf Ihrem vorhandenen Plattenleser. Kein Instrument, kein Lock-in.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/innome.de\/en\/nanodrop-alternative-specplate\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NanoDrop Alternative \u2013 SpecPlate UV\/Vis | innoME\" \/>\n<meta property=\"og:description\" content=\"SpecPlate misst 96 Proben parallel im UV\/Vis \u2013 auf Ihrem vorhandenen Plattenleser. Kein Instrument, kein Lock-in.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/innome.de\/en\/nanodrop-alternative-specplate\/\" \/>\n<meta property=\"og:site_name\" content=\"innome\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-27T14:37:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1978\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/innome.de\\\/nanodrop-alternative-specplate\\\/\",\"url\":\"https:\\\/\\\/innome.de\\\/nanodrop-alternative-specplate\\\/\",\"name\":\"NanoDrop Alternative \u2013 SpecPlate UV\\\/Vis | innoME\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/innome.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/innome.de\\\/nanodrop-alternative-specplate\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/innome.de\\\/nanodrop-alternative-specplate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg\",\"datePublished\":\"2026-05-27T14:37:23+00:00\",\"dateModified\":\"2026-05-27T14:37:25+00:00\",\"description\":\"SpecPlate misst 96 Proben parallel im UV\\\/Vis \u2013 auf Ihrem vorhandenen Plattenleser. Kein Instrument, kein Lock-in.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/innome.de\\\/nanodrop-alternative-specplate\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/innome.de\\\/nanodrop-alternative-specplate\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/innome.de\\\/nanodrop-alternative-specplate\\\/#primaryimage\",\"url\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/innome.de\\\/nanodrop-alternative-specplate\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/innome.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"NanoDrop Alternative SpecPlate\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/innome.de\\\/#website\",\"url\":\"https:\\\/\\\/innome.de\\\/\",\"name\":\"innome\",\"description\":\"Lab consumable and live cell imaging supplier\",\"publisher\":{\"@id\":\"https:\\\/\\\/innome.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/innome.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/innome.de\\\/#organization\",\"name\":\"innome\",\"url\":\"https:\\\/\\\/innome.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/innome.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/innoMEPNG.png\",\"contentUrl\":\"https:\\\/\\\/innome.de\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/innoMEPNG.png\",\"width\":125,\"height\":26,\"caption\":\"innome\"},\"image\":{\"@id\":\"https:\\\/\\\/innome.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NanoDrop Alternative \u2013 SpecPlate UV\/Vis | innoME","description":"SpecPlate measures 96 samples simultaneously in the UV\/Vis range\u2014on your existing plate reader. No instrument, no lock-in.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/innome.de\/en\/nanodrop-alternative-specplate\/","og_locale":"en_GB","og_type":"article","og_title":"NanoDrop Alternative \u2013 SpecPlate UV\/Vis | innoME","og_description":"SpecPlate misst 96 Proben parallel im UV\/Vis \u2013 auf Ihrem vorhandenen Plattenleser. Kein Instrument, kein Lock-in.","og_url":"https:\/\/innome.de\/en\/nanodrop-alternative-specplate\/","og_site_name":"innome","article_modified_time":"2026-05-27T14:37:25+00:00","og_image":[{"width":2560,"height":1978,"url":"https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/innome.de\/nanodrop-alternative-specplate\/","url":"https:\/\/innome.de\/nanodrop-alternative-specplate\/","name":"NanoDrop Alternative \u2013 SpecPlate UV\/Vis | innoME","isPartOf":{"@id":"https:\/\/innome.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/innome.de\/nanodrop-alternative-specplate\/#primaryimage"},"image":{"@id":"https:\/\/innome.de\/nanodrop-alternative-specplate\/#primaryimage"},"thumbnailUrl":"https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg","datePublished":"2026-05-27T14:37:23+00:00","dateModified":"2026-05-27T14:37:25+00:00","description":"SpecPlate measures 96 samples simultaneously in the UV\/Vis range\u2014on your existing plate reader. No instrument, no lock-in.","breadcrumb":{"@id":"https:\/\/innome.de\/nanodrop-alternative-specplate\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/innome.de\/nanodrop-alternative-specplate\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/innome.de\/nanodrop-alternative-specplate\/#primaryimage","url":"https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg","contentUrl":"https:\/\/innome.de\/wp-content\/uploads\/2026\/05\/Specplate-eingerollt-kein-Hintergrund-1-scaled.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/innome.de\/nanodrop-alternative-specplate\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/innome.de\/"},{"@type":"ListItem","position":2,"name":"NanoDrop Alternative SpecPlate"}]},{"@type":"WebSite","@id":"https:\/\/innome.de\/#website","url":"https:\/\/innome.de\/","name":"innome","description":"Laboratory consumables and live cell imaging supplier","publisher":{"@id":"https:\/\/innome.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/innome.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/innome.de\/#organization","name":"innome","url":"https:\/\/innome.de\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/innome.de\/#\/schema\/logo\/image\/","url":"https:\/\/innome.de\/wp-content\/uploads\/2026\/02\/innoMEPNG.png","contentUrl":"https:\/\/innome.de\/wp-content\/uploads\/2026\/02\/innoMEPNG.png","width":125,"height":26,"caption":"innome"},"image":{"@id":"https:\/\/innome.de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/pages\/1626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/comments?post=1626"}],"version-history":[{"count":2,"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/pages\/1626\/revisions"}],"predecessor-version":[{"id":1629,"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/pages\/1626\/revisions\/1629"}],"wp:attachment":[{"href":"https:\/\/innome.de\/en\/wp-json\/wp\/v2\/media?parent=1626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}